Engtips.

ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.

Engtips. Things To Know About Engtips.

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Bridge engineering. (7015 members) forum607 - Professional forum and technical support for engineers for Bridge engineering. Includes problem solving collaboration tools. Search. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... PE Structural CBT April 2024. I am beginning to study for the the new PE Structural (SE) exam that is a computer based test (CBT) beginning in April 2024. All prep courses I have seen online are for the existing SE exam. I am wondering if anyone else is studying for the new format SE exam and how you are going about studying.*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Geotechnical Engineers Area. Only the top forums under each heading is …

The first one is applying point load on the flange and the Beff that can be used for capacity calculation. Mu = P x a. S = beff x t^2 / 6. Mc = phi x fy x S. Second image is the scenario with stiffener added. How do we calculate the capacity for such cases? Thanks.1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the …

Chemical plant design & operations. (33961 members) forum124 - Professional forum and technical support for engineers for Chemical plant design & operations. Includes problem solving collaboration tools. Electric power & transmission & distribution. (59316 members) forum238 - Professional forum and technical support for engineers for Electric power & transmission & …

Want to know the do's and don'ts of Eng-Tips? Read FAQ731-376: Eng-Tips.com Forum Policies. English not your native language? Looking for some help in getting your question across to others or understanding their answers? Go to forum1529: Translation Assistance for Engineers.We are designing two building and we have two close columns in between so we are going to design these two columns on one pile cap with one pile. (2columns are 200 kips and 100 kips, clay soil, end bearing 4000 psi, skin friction ignored, Pile Diameter shaft is 3.3ft,bell is 10ft) we can not make it two piles …(RTTNews) - Himax Technologies, Inc. (HIMX) reported that its second quarter profit to stockholders declined to $70.64 million from $108.89 millio... (RTTNews) - Himax Technologies...Pre-calculatoin of torispherical heads acc. to ASME BPVC VIII Div.2 2023 (4.3.6.1) leads to a thinner wall than a simple cylindrical shell (4.3.3.1). Also, theJust one little thing to type or bookmark, and you'll have a fresh document in front of you. “I’m always doing some terrible workaround to try to get to Docs quickly,” our Senior T...

LB.HESSEN-THÜRINGEN GZZINSDIFF.ANL.07C/19-07 V19(34) (DE000HLB33W0) - All master data, key figures and real-time diagram. The Landesbank Hessen-Thüringen Girozentrale-Bond has a ma...

MVPs. amendale (Structural) (OP) 8 Jan 13 11:42. From reading the AISC 341 it seems to me that an OCBF would almost always be more economicaly feasible versus a SCBF to design due to SCBF capacity design requirements for beams, connections, and columns, as well as compactness restriction for braces. …

Want to know the do's and don'ts of Eng-Tips? Read FAQ731-376: Eng-Tips.com Forum Policies. English not your native language? Looking for some help in getting your question across to others or understanding their answers? Go to forum1529: Translation Assistance for Engineers.7 Feb 16 11:02. I am designing a isolated footing in SAFE but I am confused that how to check the footing against uplift? Soil pressure are coming as mentioned below. Against dead load Max = -9.08 KN/m^2 and Min = -18 KN/m^2. Against wind load is Max = 53.83 KN/^m2 and Min = -38.74 Kn/m^2. footing is safe against uplift????Update: My final solution was to drill and epoxy #3 bars at 24" OC (every 3 CMU courses) with 18" of embedment into the existing walls. However, there was an ice storm in late December that revealed more structural problems with the building only to be exacerbated by the winter storm from February.Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange. Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search.

22 hours ago · The Eng-Tips staff will check this out and take appropriate action. Close. Reply To This Thread Posting in the Eng-Tips forums is a member-only feature. Rules of Thumb - Structural Engineering Other Technical Topics FAQ - Eng-Tips - Free download as PDF File (.pdf), Text File (.txt) or read online for free. For a "rule of thumb" …Ignition, Combustion and Detonation engineering. Laser engineering. Mechanical Seal engineering. Mechanical Acoustics/Vibration engineering. Optical systems engineering. Pipelines, Piping and Fluid Mechanics engineering. Pump engineering. Storage tank engineering. Valve engineering.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng … Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search.

Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum.

thread404-515636. Dynamo2000 (Mechanical) (OP) 19 Jan 24 21:00. Very recently in the news was an invention called the Holo Tile Floor created by Disney's National Inventors Hall of Fame member Lanny Smoot. This creation allows the user to "walk" in any direction without moving anywhere! The floor shifts to compensate for the user's leg … Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for ASME (mechanical) Code Issues. Includes problem solving collaboration tools. All the handrails have to meet the requirements. Loading one side vs the other side is really irrelevant to the handrails and its connections. If there is some loading you are concerned about the in the elements supporting the handrails you might want to consider the loading on each of them simultaneously or perhaps just one side.The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.i have got into trouble with linear gap element. My model like flange contact have 500000 dof. i use linear gap method in axial direction and rbe2 (Fy~Mz) in other direction. unfurtunately, i just obtain some fatal message "fatal message 1012" no matter what i do. (try to change buffsize) or wirte down "nastran system (1015)=1".See thread507-434895: Tension Field Action - End panels in Old Codes. BA. rb1957 (Aerospace) 7 Sep 20 22:16. the author makes the point that the end bays usually don't have the stiffener at the extreme end of the beam, and so the web cannot develop the shear buckles. In the example R13 posted these end panels aren't doing anything to react the ...China and Europe remain the most important electric vehicle markets. Electric vehicles (EVs for short) are no longer just cool toys reserved for wealthy futurists. They are becomin...Three way valve has a one inlet and two outlets. It is not mixing valve. The flow of media through such a valve is through an input and an output. One output is closed. What if the piping of the installation is built in such a way that the second output also receives the media. Physically, the two fluids do not mix because the valve is only ...

The caustic scrubber is used to absorb the sour gases like H2S and CO2. To design this, you need to consider the system as an absorption column. For that you need to calculate how many equilibrium stages you have. Do not forget you have , at least, one chemical reaction (H2S + 2NaOH --> Na2S + 2H2O) if your stream doesn't have CO2.

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …

I think many engineers seem to miss this concept as I have seen many designs with a single hairpin where the hairpin appeared to have been calculated based solely on the area of steel into an un-reinforced slab. hdp321 (Structural) (OP) 6 Mar 23 00:01. There’s about 95 kips of thrust per column.John Werner. 2023, the writer argues, was the year in which we learned in a theoretical way about how large language models work. 2024, by contrast, is going to be …Mar 22, 2023 · From reading XR250s posts I think this is how he approaches it as well. 3. YoungGunner (Structural) 23 Mar 23 15:22. Having worked in residential for 7 years now, I have a few thoughts on the matter: First off, the IRC already shows questionable engineering compared to our "big boy" design standards/codes. Chemical process engineering. (26899 members) forum798 - Professional forum and technical support for engineers for Chemical process engineering. Includes problem solving collaboration tools. Forum. Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality.Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net Joined March 2009. 124 Following. 295 Followers. Tweets & replies. Media.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …The reason is carbon content below 0.03% would be considered 304L per the SA 240 material specification, and limited to 1000 deg F. When you have dual grade certification 304L/304, the 0.04% or higher carbon comes into play for creep strength and one must review the MTR for specific use. SnTMan (Mechanical) 14 …

Dystonia is a movement disorder. It causes involuntary, often painful, contractions of your muscles. Learn about causes, symptoms, and what can help. Dystonia is a movement disorde...Not every workplace makeover needs to involve a spending spree at Ikea and more LEDs than a flight control panel. Today's featured workspace just needed a little tidying and cable ...Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering …Instagram:https://instagram. coin laundry bowie mdriverann onlyfans nudesholly ava only fanseras tour tickets 2024 Fluid Power engineering. (8474 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search. sunset time in pakistanpulleys gizmo answer key Design of Footing with very large moment. Good day! I believe this one is just simple, what makes it complex is the large moment to be considered in the design. I have an anchored steel pole with base reactions M=220kN-m, P=28kN, V=14kN,. (M=moment, P=Axial, V=Shear). I have already design the pedestal to … haunted mansion showtimes near amc white marsh 16 Specifically, bollards for protection are angled toward the direction of the expected threat; this provides an added measure of strength, since there's no reason to make the bollards be symmetrical in protection direction/angle. Angling the bollard could reduce the required thickness of the bollard, since the collision energy is directed ...*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Chemical Engineers Area. Only the top forums under each heading is …