Engtips.

Its total height is 140 mm, where height of steel deck is 60 mm and height of concrete above slabs is 80 mm, so I've put that both membrane and bending thicknesses are 140mm = 0,14m. As a material I've chosen concrete C30/37 defined in Materials (I'll attach my model in SAP2000 at the end of the post). This concrete's Weight per Unit Volume is ...

Engtips. Things To Know About Engtips.

Pre-calculatoin of torispherical heads acc. to ASME BPVC VIII Div.2 2023 (4.3.6.1) leads to a thinner wall than a simple cylindrical shell (4.3.3.1). Also, theEng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net Joined March 2009. 124 Following. 295 Followers. Tweets & replies. Media.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Wind load on the superstructure may be calculated as. 150 psf x A x L. Where 150 psf is the wind pressure (Check also your state or local requirements for different criteria), A is the area of the superstructure in elevation (Curb height, slab height, haunch height, girder and any superelevation), and L is the tributary length …

Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …Eng-Tips Groups Engineering Language/Grammar Skills Engineers with Hobbies Local Exhaust Ventilation NICET Certification, training and education Pats' Pub Translation Assistance for Engineers. People Aeronautics & Space Engineers Activities Aeronautic & Space engineering general discussion Aircraft engineering Rotorcraft engineering …

March 12, 2024. Are you helping your patients with type 1 diabetes make the most of continuous glucose monitoring (CGM) devices? At the Advanced Technologies & …

The answer can be found in a textbook or your lecture notes from school. Shear design formulas in EC2 are based on strut-and-tie models, and when the distance of the critical section is "d" or less than that, a large part of the shear is transferred by arch action (a compression strut) directly to the support.Dynamic Cone Penetrometer (DCP) is a very poor tool for evaluating modulus of subgrade reaction (k) or modulus of rupture (M R).In my opinion, you would be better off guessing - at least then you would be applying your judgement to the problem.March 12, 2024. Are you helping your patients with type 1 diabetes make the most of continuous glucose monitoring (CGM) devices? At the Advanced Technologies & …Product Guide Directory. Learn About Each of Eng-Tips' Industrial & Technology Marketing Solutions. Grow Brand Awareness. Build Purchase Intent. Generate Leads. Access The …Bell 407 Boeing VR-7 Narramore 8%. Bell 409 YAH-63 Wortmann FX 69-H-083 Wortmann FX 69-H-083. Bell 412 Boeing VR-7 Wortmann FX 69-H-080. Bell 427 Boeing VR-7 Narramore 8%. Bell 47G-2 H-13G wood blades NACA 0017 NACA 0011. Bell 47G-2 H-13H metal blades NACA 0015 NACA 0015. Bell 47J HUL wood blades NACA …

For starters, you can successfully weld 5052 H32 (not heat treatable aluminum alloy) to 6063 T5. However, the heat from welding will locally soften the 5052 and the 6063. If this is not a highly stressed component or used under cyclic loading conditions, you should be ok. The following web site has various filler …

John Werner. 2023, the writer argues, was the year in which we learned in a theoretical way about how large language models work. 2024, by contrast, is going to be …

Specifically, bollards for protection are angled toward the direction of the expected threat; this provides an added measure of strength, since there's no reason to make the bollards be symmetrical in protection direction/angle. Angling the bollard could reduce the required thickness of the bollard, since the collision energy is directed ... Civil/Environmental engineering general discussion. (46863 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum. woman with red coat walking up the stairs to the clouded sky Cancer Matters Perspectives from those who live it every day. Your email address will not be published. Required fields...At the moment we have 870525 registered users, who have published 99622 materials and shared 554052 comments. Englishtips.org was launched in 2005. In the last 24 hours …Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …We've been conditioned to tie rewards to travel. But by focusing on rewards beyond travel, we can expand our points and miles freedom. Increased Offer! Hilton No Annual Fee 70K + F...Not every workplace makeover needs to involve a spending spree at Ikea and more LEDs than a flight control panel. Today's featured workspace just needed a little tidying and cable ...

Subject: Section VIII-1, UCS-85 (b) and (e) Date Issued: May 31, 1984. File Number: BC82-563. Related Documents: Question (1): A dished head made of P-No. 1 Gr. Nos. 1 and 2 material with a thickness of less than 1¼ in. is hot pressed at a temperature of 1750°F. Are test specimens required under UCS-85 of Section VIII, Division 1, to ...The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites … Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …Hosting a wine tasting can be a truly memorable experience. Learn how to host a wine tasting. Advertisement Nothing contributes more significantly to your wine experience than tast...Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.I attached a drawing just in case I can't explain myself clear enough. Anyway, I read that 'A relief valve is only needed if no other measures are provided to detect low flow conditions and shut down the centrifugal pump to prevent damage', well in my situation, there isn't a flow measuring instrument installed upstream of …

The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …

The nosing provides clearance space for your heel to drop on the tread. If there were no nosing, your heel might hit the riser and you will stumble forward (and probably fall if you are not holding n the handrail). msquared48 (Structural) 20 Apr 09 19:27. To encourage tripping as you go up the stairs.*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Geotechnical Engineers Area. Only the top forums under each heading is …From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—...The calculator checks the number of nails required in each member and OSB shear strength. We based our design on several other Eng-Tips articles regarding OSB gusset plates. OSB strengths are based on the APA Panel Design Specification, and have variable strengths depending on the direction of force. We …Dynamic Cone Penetrometer (DCP) is a very poor tool for evaluating modulus of subgrade reaction (k) or modulus of rupture (M R).In my opinion, you would be better off guessing - at least then you would be applying your judgement to the problem.Brick grows with time, and that can lead to cracking at the thinnest sections, and the two sections in your photos are thin. This cracking in veneer is not indication of settlement or other structural problems, so if it bothers you, get a mason to repoint it. Make sure he knows what he is doing, as amateur repairs can stand out worse than the ... Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search.

The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …

Defying stereotypes. At four feet 11 inches, and 73 kilograms, Dolly Singh stands out from the crowd of star yogis on Instagram who have come to be known for their slim waists, mus...Joints spacing: • Rule of thumb is 24 to 36 times the thickness (gives the spacing in mm/inches). • Keep the thickness variation to -5mm (-1/4") / +10mm (3/8"), and the subgrade as flat as possible with no abrupt change greater than 15mm (1/2") in about 1.2m (4'). This keeps the "sudden" restraint potential down.Specifically, bollards for protection are angled toward the direction of the expected threat; this provides an added measure of strength, since there's no reason to make the bollards be symmetrical in protection direction/angle. Angling the bollard could reduce the required thickness of the bollard, since the collision energy is directed ...Steel Stair Seismic Design. I have posted a couple of threads regarding this subject in the past, but I would like to post a more thourough question regarding providing seismic design on steel stairs. I have a particular project which is in the Missouri area and is governed by the 2006 IBC and ASCE 7-05. I have …While specific laws vary by state, the general process of assessing real property is similar across the country. If you own real estate, it will be assessed, and that assessment w...Electric power & transmission & distribution. (59316 members) forum238 - Professional forum and technical support for engineers for Electric power & transmission & …My 1937 copy of Trautwines Civil Engineers Reference Book gives: "Normal reinforcing steel ultimate strength of between 50,000 - 70,000 lbs per sq in with elastic limit (yield) at 25,000 - 35,000 lbs per sq in. Cold working the bars will raise the elastic limit to 40,000 - 50,000 lbs per sq in. Deformed bars have a higher elastic limit claimed ... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.

Civil/Environmental engineering general discussion. (46863 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum. The U.S. Department of Health and Human Services (HHS) is aware that Change Healthcare – a unit of UnitedHealth Group (UHG) – was impacted by a …Deflections under seismic loading - Part 2. It's my understanding that 4.1.8.11.3) d) v) allows us to use a larger period specifically to check seismic deflections. This means I'll have a different base shear than my regular elastic analysis, so I always run a distinct case anyways.Ayurveda. Unani. Homeopathy. Cowpathy. You’ve heard of ayurveda, the traditional Indian medical science. So have you about Unani, the Perso-Arabic healing science. Then there is ho...Instagram:https://instagram. what time is sam's club open until todayweather underground ojaio'reilly horariopollen count madras oregon Dynamic Cone Penetrometer (DCP) is a very poor tool for evaluating modulus of subgrade reaction (k) or modulus of rupture (M R).In my opinion, you would be better off guessing - at least then you would be applying your judgement to the problem.woman with red coat walking up the stairs to the clouded sky Cancer Matters Perspectives from those who live it every day. Your email address will not be published. Required fields... ups horariosunscramble condor The U.S. Department of Health and Human Services (HHS) is aware that Change Healthcare – a unit of UnitedHealth Group (UHG) – was impacted by a …For starters, you can successfully weld 5052 H32 (not heat treatable aluminum alloy) to 6063 T5. However, the heat from welding will locally soften the 5052 and the 6063. If this is not a highly stressed component or used under cyclic loading conditions, you should be ok. The following web site has various filler … eddie coker deputy I attached a drawing just in case I can't explain myself clear enough. Anyway, I read that 'A relief valve is only needed if no other measures are provided to detect low flow conditions and shut down the centrifugal pump to prevent damage', well in my situation, there isn't a flow measuring instrument installed upstream of …JStephen (Mechanical) 13 Feb 17 15:46. If you don't find anything specific to this situation-. Treat the flange as a triangular wedge spreading out at 45 degrees each side from the bolt hole and checking bending at the web. For a one-off design, it may be cheaper to weld a stiffener in than to show it isn't needed.Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …